Cloud Platform · Edge AI · IT + OT

LANAWARE™ Cloud & Edge AI
Passive by default. Your data never leaves.

A single appliance that quietly inventories every device on your network — IT and OT — without ever probing harder than you allow. Scan data stays on your site or in our Ontario datacentre — never a hyperscaler. Auditors get the evidence they ask for. Your controls engineers get a tool they can trust on the plant floor.

FIG.01 · NODE · RADIAL DISCOVERY SVR.01 SW.07 PLC.03 HMI.02 AP.04 CAM.11 RTU.02 EDGE NODE LANAWARE / EDGE N : 260 E : 480 S : 040 W : 040
Why LANAWARE Cloud & Edge AI

Four reasons you actually want this on your network.

Most asset-discovery tools were built for IT estates and bolted on for OT later. LANAWARE Edge was built the other way around — industrial-safe from day one, on-prem by default, and audit-ready as a side effect of normal operation.

01
PLC-safe by design

It won't crash your controllers.

A five-tier scan model — from pure passive listening to full active — runs per device, never harder than its assigned tier. Plug a node into a 25-year-old PLC and nothing happens to that PLC. The tier is auditable, operator-controlled, and recorded against every device.

02
Your data, your network

Scan data never has to leave.

Run in Local Mode and scan data physically does not leave the customer's network — verifiable in the box's outbound traffic, not just our policy doc. Run in Cloud Mode and the only thing that hits the cloud is what you choose to sync, landing in our Ontario private DC. No hyperscaler in the path. Ever.

03
Audit-ready by default

The evidence auditors actually ask for.

Inventory, configuration baselines, vulnerability posture, and backup-restore records mapped to NERC-CIP, IEC 62443, NIST CSF, and NIS2 — exported as PDF or CSV on demand. Generated as a side effect of normal operations, not a quarterly screenshot scramble.

04
IT + OT in one place

Every device. One pane.

Servers, switches, workstations, cameras, phones — alongside PLCs, HMIs, RTUs, drives, and IO modules — discovered, classified, and monitored continuously from the same node. Vendor, model, firmware, role, Purdue level, risk score: every device in one view.

The full picture

Want the technical detail? Open any panel.

Everything below is closed by default. Click a panel to expand it — or skip to who buys it or book a demo.

01 What the node actually does — the seven jobs Discovery · Classification · Vulns · Reports
Section 01 / What it does

Seven jobs, one box.

A LANAWARE Edge Node plugs into your switch and quietly does the work that traditionally required a half-dozen agents, scripts, spreadsheets, and consultants. No endpoint installs. No proprietary tap. No agent on the PLC.

01

Maps the network

Continuously discovers every device on every subnet — IT (servers, switches, workstations, printers, cameras, phones) and OT (PLCs, HMIs, RTUs, drives, IO modules).

02

Classifies each device

Vendor, model, firmware version, role (workstation / server / PLC / camera / etc.), and Purdue-model zone for industrial environments — with confidence scoring and a full audit trail of how the identification was made.

03

Detects vulnerabilities

Cross-references discovered software against national vulnerability databases and the known-exploited vulnerabilities catalog. Operators see a prioritised risk score per asset and per site.

04

Polls health metrics

SNMP-based metrics from network gear — CPU, memory, interface bandwidth, error counts, temperatures — stored in a local time-series database for trending and alerting.

05

Detects industrial protocols

Modbus, S7, EtherNet/IP (CIP), OPC-UA, DNP3, IEC 61850 GOOSE / MMS, and BACnet — safe by design via the five-tier scan model. The node won't probe a device harder than its assigned tier permits.

06

Maps physical topology

Reads LLDP and CDP advertisements to reconstruct the actual switch-port-to-device wiring of the site, visualised in browser as a force-directed graph or a hierarchical Purdue-model layout.

07

Generates evidence-ready reports

PDF and CSV exports tailored to compliance frameworks — NERC-CIP, IEC 62443, NIST CSF, and NIS2 — with the inventory, configuration baselines, and vulnerability posture auditors actually ask for.

From the product · Assets

Every device. Classified, scored, scoped.

The flagship view in the LANAWARE Edge Node UI — every device the node has seen, with identity, role, Purdue level, vendor, OS, services, top peer, protocols, packet counts, and a risk indicator. In Scope rows are actively probed; Not in Scope rows are watched passively or excluded entirely.

LANAWARE monitored assets view in dark theme
Fig. 01 · LANAWARE Edge Node — Assets
36 devices9 classified5 OT listenersLive
02 How it stays PLC-safe — the full tier & probe-depth model 5 tiers · 3 depths · 14 industrial protocols
Section 02 / Industrial-safe by default

Five tiers. Per device. Auditable.

Most asset-discovery tools weren't designed with PLCs in mind. LANAWARE Edge is. The aggressiveness of every scan is governed by a five-tier model that operators set per zone and per device — and the node will never probe harder than its tier permits.

Tier 0
Passive Listening

Pure observation. The node listens to broadcast and mirror traffic only. PLC-safe — won't crash a legacy controller.

Tier 1
Discovery Probes

ARP sweeps and ICMP echo. The lightest active footprint that still produces a real-time inventory.

Tier 2
Targeted SNMP

Vendor-aware SNMP queries against managed network gear, with read-only credentials. No payload writes.

Tier 3
Safe OT Probe

Read-only industrial-protocol identification — Modbus, CIP, S7, BACnet, OPC-UA — bounded by protocol-specific safety rules.

Tier 4
Full Active

Full TCP/UDP service scan and version detection. Reserved for IT segments. Never applied to OT devices without explicit operator opt-in.

SAFE AGGRESSIVE
From the product · Purdue model

Auto-generated Purdue model. Boundary crossings flagged.

The Edge Node organises discovered assets into the IEC 62443 / Purdue reference model — L0 Field through L5 External — and flags every flow that crosses a zone boundary in red. This is how you find the rogue Internet path from a control device, or the supervisory station chatting to L5 it shouldn't be.

LANAWARE Edge Node UI — Purdue-model topology with boundary crossings
Fig. 02 · LANAWARE Edge Node — Purdue Topology
36 nodesL0–L5Boundary crossings
Industrial protocols detected by the LANAWARE Edge Node
OTEtherNet/IP & CIP OTS7 / PROFINET OTModbus TCP OTFINS OTSLMP / MELSEC OTADS / AMS OTSRTP OTDNP3 OTIEC 61850 MMS OTIEC 61850 GOOSE OTOPC-UA BABACnet/IP ITSNMP v1 / v2c / v3 ITLLDP / CDP
Beneath the tiers · Probe depth

Three depths. Per protocol.

Inside the tier model, every industrial-protocol probe runs at one of three explicit depths — operator-controlled, fully audited, and surfaced in the asset record so engineers always know how a device was identified.

01

Fingerprint

Port-open detection plus protocol confirmation. Nothing is read from the device beyond what a TCP handshake already reveals.

Safe for Tier 0 environments
02

Read

Vendor identifier, model, firmware revision, and basic tag or register enumeration. Read-only, scoped, and requires explicit per-device safety-tier approval.

Requires Tier 3 approval
03

Assess

Security posture: unauthenticated-access checks, default credentials, risky-config detection. Reserved for IT segments or operator-sanctioned OT pilots.

Reserved for Tier 4
From the product · Risk posture

Depth 03 in action. Risk, prioritised.

When operators authorise Depth 03 / Assess on an IT segment or sanctioned OT pilot, the Edge Node cross-references discovered software against vulnerability databases and produces a single rolled-up risk score per asset and per site. Severity, CVSS, source, discovery time, status, and disposition — all in one place, all exportable.

LANAWARE Edge Node UI — Risk Posture & Vulnerabilities
Fig. 03 · LANAWARE Edge Node — Risk Posture
Risk 73 / 10013 findingsNVD-NIST · KEV
From the product · Traffic health

Continuous traffic monitoring. OT-aware.

The Edge Node continuously profiles traffic shape: throughput trends, per-flow jitter, cyclic-flow detection, packet-size distribution (the unmistakable bimodal pattern of OT environments), TCP retransmits, dup-ACKs, zero-windows, and out-of-order. The first place engineers look when 'the network feels slow.'

LANAWARE Edge Node UI — Traffic Shape & Performance
Fig. 04 · LANAWARE Edge Node — Traffic Shape
984 Kbps peak2 cyclic flows100 TCP anomalies
03 Vendor & protocol coverage IT · OT · Substation · Building automation
Section 03 / Built to integrate

Speaks every vendor on your network.

A LANAWARE Edge Node ships with vendor-aware knowledge built in — fingerprinting profiles, SNMP MIBs, vendor-ID decoders, and firmware-to-vulnerability mappings — for the major IT-networking, industrial-automation, substation, and building-automation vendors. The library is curated, audited, and expanding with every release.

Class · IT / Network

Networking & Security

Deep vendor-specific support for the network gear your IT team already runs — discovery, classification, SNMP polling, and configuration awareness.

Cisco
Switches · Routers · Wireless

Full vendor-aware SNMP profiles, model and firmware fingerprinting, CDP topology reconstruction, and IOS / IOS‑XE / NX‑OS classification across enterprise and industrial lines.

Fortinet
Firewalls · UTM · Switching

FortiGate, FortiSwitch, and FortiAP discovery with firmware-version awareness and Security Fabric topology mapping. Vulnerability posture cross-checked against the public catalog.

Aruba
Switching · Wireless · Edge

CX and ProCurve switching, plus Instant‑On and Aruba Central‑managed access points. Classification, port-level topology, and health metrics via vendor-specific SNMP profiles.

Class · OT / Industrial Automation

PLCs & Plant Control

Protocol-aware identification for the control-system vendors operating your plant floor — safely, inside the five-tier scan model.

Rockwell / Allen-Bradley
CIP · EtherNet/IP

ControlLogix, CompactLogix, MicroLogix, GuardLogix, and PowerFlex drives. Chassis enumeration plus device-class and firmware fingerprinting.

Siemens
S7 · PROFINET

SIMATIC S7-300, S7-400, S7-1200, and S7-1500 identification over the S7 family. SCALANCE switches recognised via vendor-aware SNMP profiles.

Schneider Electric
Modbus · CIP

Modicon M340, M580, and Quantum identification over Modbus TCP, with CIP support for EcoStruxure-family controllers.

Omron
FINS

CJ, CP, NJ, and NX series identification over the FINS protocol — read-only fingerprinting with operator-controlled depth.

Mitsubishi
SLMP · MELSEC

Q-series, FX-series, and iQ-R / iQ-F identification over SLMP / MELSEC, with model and CPU-version fingerprinting.

Beckhoff
ADS · AMS · EtherCAT-CIP

TwinCAT systems identified over the ADS / AMS protocol, plus EtherCAT-to-CIP gateways picked up by the CIP probe family.

GE / Emerson
SRTP

Series 90, RX3i, and PACSystems controllers identified over the SRTP protocol, with model and firmware capture.

… and growing
Customer-requested vendors prioritised every release
Class · Substation & Building Automation

Power, IEDs & BAS

Substation IEDs and building-automation controllers, identified over IEC 61850 MMS, DNP3, and BACnet/IP — including vendor-ID decoding for devices masquerading as generic.

ABB
IEC 61850 MMS

Substation IEDs and protective relays identified over IEC 61850 MMS with logical-node enumeration.

SEL
IEC 61850 MMS · DNP3

Schweitzer Engineering Labs protective relays and RTUs identified across both 61850 and DNP3 channels.

Honeywell
BACnet/IP

Building-automation controllers identified via BACnet vendor-ID decoding across the broader Honeywell product family.

Johnson Controls
BACnet/IP

Metasys and broader JCI controllers picked up over BACnet/IP with full vendor-ID identification.

Trane
BACnet/IP

Tracer SC and broader Trane HVAC plant controllers identified via BACnet vendor decoding.

Distech Controls
BACnet/IP

EC-Net and ECLYPSE controllers identified with full vendor-ID decoding over BACnet/IP.

+ Echelon, TAC/Schneider, Beckhoff EtherCAT-CIP gateways, & any IEC 61850-compliant IED
Curated vendor library · Vendor-ID decoders · Customer-requested integrations prioritised
Reference · Protocol coverage matrix

Every protocol. By design.

A condensed view of the industrial-protocol library shipped with every LANAWARE Edge Node. Read-only by default; deeper interrogation gated by the tier and probe-depth models.

Protocol
Coverage
Representative vendors
EtherNet/IP & CIP tcp/44818
Discrete & Process
Rockwell · Allen-Bradley (ControlLogix, CompactLogix, MicroLogix, GuardLogix), Schneider, Beckhoff EtherCAT-CIP gateways
S7 / PROFINET tcp/102
Discrete & Process
Siemens SIMATIC S7-300, S7-400, S7-1200, S7-1500
Modbus TCP tcp/502
Universal fallback
Schneider Modicon (M340, M580, Quantum) — and effectively every other vendor's PLCs as a fallback identification path
FINS udp/9600
Discrete Automation
Omron CJ · CP · NJ · NX series
SLMP / MELSEC tcp/5007
Discrete Automation
Mitsubishi Q · FX · iQ-R · iQ-F series
ADS / AMS tcp/48898
Process Control
Beckhoff TwinCAT systems
SRTP tcp/18245
Process Control
GE · Emerson Series 90, RX3i, PACSystems
DNP3 tcp/20000
Power · Water · Energy
Power-grid RTUs & IEDs, water / wastewater SCADA — vendor-agnostic
IEC 61850 MMS tcp/102
Substation IEDs
ABB, Siemens, GE, SEL, and any IEC 61850-compliant IED
OPC UA tcp/4840
Cross-vendor standard
Any OPC-UA server — fingerprint and protocol confirmation
BACnet/IP udp/47808
Building Automation
Trane, Johnson Controls, Honeywell, Schneider (TAC), Echelon, Distech — with full vendor-ID decoding
Read-only by default Deeper probes gated by tier + depth Vendor-IDs decoded from protocol stream
From the product · Topology designer

Vendor-aware discovery, visualised.

Every protocol probe and SNMP profile feeds the Network Map Designer — the Edge Node's interactive topology view. Switch between hierarchical, force-directed, Purdue, or floor-plan layouts; export to PNG, SVG, DOT, Cytoscape, or CSV; and overlay LLDP, CDP, and manual edges to reconstruct the actual switch-port-to-device wiring of the site.

LANAWARE Edge Node UI — Network Map Designer (Hierarchical layout)
Fig. 05 · LANAWARE Edge Node — Network Map Designer
84 nodes96 links13 LLDP · 5 CDP78 inferred
04 Cloud or Local deployment — same node, two modes MSP fleet · Data-sovereign · On-prem
Section 04 / Two ways to deploy

Cloud or Local. Same node.

Every LANAWARE Edge Node is the same piece of hardware running the same software. What differs is whether scan data syncs to LANAWARE Cloud — or never leaves the customer's network at all.

Deployment · 01

Cloud Mode

Fleet-managed · MSP-ready

The edge node syncs its inventory and findings to LANAWARE Cloud. Operators view the entire fleet from a single portal — multiple customers, multiple sites under one management pane — with cross-site analytics, role-based access, and centralised report distribution.

  • Best forMSPs, multi-site operators
  • Cloud syncInventory · findings · telemetry
  • ViewSingle fleet-wide portal
  • Customer controlPer-tenant data isolation
Deployment · 02

Local Mode

Data-sovereign · regulated

Scan data never leaves the customer's network — verifiable in the box's outbound traffic, not just policy. Only license status and node health traverse the cloud connection. Built for financial, defence, and regulated customers with hard data-residency mandates.

  • Best forDefence, finance, regulated OT
  • Cloud syncLicense · health only
  • ViewOn-prem browser UI
  • Customer controlAbsolute data sovereignty
05 Live operations — 24/7 monitoring & asset lifecycle SLA · Behavioural baselining · Firmware drift · PLC change tracking
Section 05 / 24/7 continuous monitoring

From inventory snapshot to live operational truth.

Discovery is the first frame. Monitoring is the movie. Once a LANAWARE Edge Node has fingerprinted a site, it never stops watching — every device, every protocol flow, every config drift, every off-hours conversation. Anomalies don't sit in a log waiting for someone to scroll past them. They page a human at Completely Managed's NOC under contractual SLA.

01

Always-on industrial protocol watch

Continuous passive listening on every defined OT zone — Modbus, S7, EtherNet/IP (CIP), OPC-UA, DNP3, IEC 61850 (GOOSE / MMS), and BACnet. Flow counts, talker maps, polling cadence, and baseline traffic shape are updated minute-by-minute, not hourly.

02

Per-device health & availability heartbeats

ICMP, SNMP v1/v2c/v3, and protocol-native pings on PLCs, HMIs, RTUs, drives, IO modules, switches, firewalls, and historians. Each device contributes to a per-zone health roll-up and a site-level operational score visible from a single pane.

03

Behavioural baselining & anomaly detection

Every device gets a baseline of its normal protocol partners, polling frequencies, and traffic envelope. Deviations trip: new talker pairs, off-hours activity, protocol changes on a known-quiet port, payload-size shifts, and unexpected outbound traffic from a control-zone device.

04

SLA-driven human response — not just a notification

Alerts route through CM's NOC with documented runbooks per alert class and a contractual response SLA. Critical OT events get a human acknowledgement, not a Slack ping into the void. This is the difference between an alerting product and a monitoring service.

05

Time-series telemetry, retained on-prem

Local time-series database on the Edge appliance stores SNMP counters, protocol-flow metrics, latency, and packet-loss for trending and post-incident forensics. Retention configurable 30–365 days on the node; longer on the customer's chosen backing store.

06

Alarm correlation across IT & OT

A switch port flapping that happens to carry a SCADA tunnel stops being two unrelated tickets. The Edge Node correlates link-state events with the application traffic on top of them and presents the operator with one story, not two.

07

Cross-fleet pattern visibility (Cloud Mode only)

Operators in Cloud Mode see the same anomaly pattern across sites — a vendor firmware that's flapping in three plants, a new outbound connection appearing in five customers — and respond once, not five times. This is where MSP-scale advantage lives.

noc.lanaware.com — Live alert stream · last 5 min
● Streaming
15:42:08 LA-NODE-07 · PLC-104 unreachable for 90s — Site Delta, Cell 3 Critical SLA · 5m
15:41:32 LA-NODE-03 · New Modbus talker pair: 10.32.4.18 → PLC-22 (baseline deviation) Anomaly SLA · 30m
15:40:11 LA-NODE-01 · Switch SW-CORE-A interface Gi1/0/12 errCRC counter +28 in 60s Warning SLA · 4h
15:39:54 LA-NODE-09 · Tier-3 OT probe completed — 217 assets, 0 new vulns Resolved —
15:38:02 LA-NODE-05 · Off-hours OPC-UA session opened from EWS-12 (after 22:00 schedule) Info SLA · 24h
< 60s
MTTD · protocol drift
24×7
NOC coverage
99.95%
Telemetry availability
100%
Critical alert ack
Section 06 / Asset lifecycle management

Every PLC's biography, not just its name tag.

A point-in-time inventory tells you what's on the network today. Lifecycle management tells you when each device arrived, what firmware versions it has run, which slots have been swapped, which configs were changed, who changed them — and how many days until vendor support ends. The LANAWARE Edge Node maintains a continuous biography of every asset under management.

01

Firmware drift & version history

Every controller, switch, HMI, drive, and managed RTU has its firmware tracked over time, not just snapshot. Approved-version policy per zone. Unauthorised firmware change → alarm. Rollback-to-known-good supported where vendor tooling permits.

02

PLC program checksum & change tracking

Online checksums and program-counter snapshots for Allen-Bradley, Siemens, Schneider, GE, Mitsubishi, Omron, and Beckhoff PLCs. Any logic change since last baseline raises a tracked event with who/what/when metadata.

03

Switch & firewall config diffing

Daily configuration captures from network gear (Cisco IE, Stratix, Hirschmann, Moxa, Fortinet, Aruba) with line-by-line diffs against the last known-good. Diffs cross-referenced against approved change tickets.

04

Hardware change detection

Module swaps, IO card moves, slot reorganisations, blade replacements — detected via SNMP, CIP / PROFINET / S7 introspection, and physical-port LLDP/CDP. The plant cabinet telling you what changed, not the other way around.

05

End-of-life & end-of-support warnings

Vendor lifecycle advisories ingested and matched against your live fleet. Devices flagged by EOL date, criticality, and current exposure — so spares ordering and migration planning is data-driven, not retroactive.

06

Audit-ready chain of custody

Every change recorded above carries a who-what-when record, digitally signed and exportable. Designed to satisfy NERC-CIP CIP-010 baseline configuration, IEC 62443-2-4 change management, and ISA-95 audit requests without three weeks of spreadsheet archaeology.

07

Spares & MTBF intelligence

Cross-references what's in your spares cabinet against what's failing in the plant. Mean-Time-Between-Failures per part number per site, rolling up across customers in Cloud Mode so the fleet learns from itself.

08

Lifecycle data feeds CMMS & CMDB

Standards-based webhooks and REST APIs push asset state into the customer's existing CMMS (Maximo, SAP PM, eMaint, UpKeep) and CMDB (ServiceNow, BMC, Jira Service Management). One source of truth — without ripping out the system the maintenance team already lives in.

PLC-104
Siemens S7-1515-2 PN
L2 · Cell 3 · Site Delta
2024-08-14 Onboard Asset enrolled · Firmware V2.9.2 · Slot baseline captured edge-node-07
2025-02-03 Firmware Firmware upgrade V2.9.2 → V2.9.6 (vendor advisory SSA-389290) jchang@cm
2025-06-22 Module swap Slot 4 module replaced · 6ES7522-1BL01 → 6ES7522-1BL10 site-engineer
2025-11-11 Program Online checksum delta detected · diff vs. baseline = 47 instructions edge-node-07
2026-04-09 EOL warning CPU 6ES7515-2AN03-0AB0 enters limited support 2027-10-01 — 540 days vendor advisory
2026-05-21 Baseline Configuration baseline re-attested · NERC-CIP-010 R1.1 evidence exported audit-export
100%
Change events tracked
365d
Standard event retention
8
CMMS / CMDB integrations
CIP-010
Native audit export
06 Backups & plant-floor HA — ECHO + MVE PLC programs · Historians · Application-consistent · HA without a datacentre
Section 07 / ECHO backup & recovery

When something does break, recovery is a non-event.

ECHO is Completely Managed's backup and disaster-recovery service — purpose-built for industrial assets. PLC programs, HMI projects, SCADA tag databases, Ignition gateways, WinCC archives, historians, and the SQL / Oracle / PostgreSQL back-ends behind them, all backed up on a schedule that respects production. Where backups live is the customer's choice. It is never the public cloud.

What ECHO protects

PLC · Logic & data
Controller programs
  • Allen-Bradley RSLogix / Studio 5000
  • Siemens TIA Portal / Step 7
  • Schneider Unity / Control Expert
  • GE Proficy / PAC Machine Edition
  • Mitsubishi GX Works / iQ-Works
  • Omron Sysmac Studio
  • Beckhoff TwinCAT 3
HMI · Visualization
HMI projects
  • Rockwell FactoryTalk View SE / ME
  • Siemens WinCC (Classic & Unified)
  • Wonderware / AVEVA InTouch
  • GE iFIX / CIMPLICITY
  • Inductive Automation Ignition (Vision & Perspective)
  • Citect SCADA
SCADA · Tag DB
SCADA databases
  • Ignition Gateway backup (.gwbk)
  • iFIX / CIMPLICITY databases
  • WinCC OA project archives
  • Wonderware Galaxy repository
  • Citect projects & runtime
Historian · Time-series
Historian archives
  • OSIsoft / AVEVA PI System
  • Wonderware Historian
  • Canary System
  • Ignition Tag Historian
  • InfluxDB / TimescaleDB on-site stores
Database · Application-consistent
Industrial databases
  • Microsoft SQL Server (Always-On aware)
  • Oracle Database (RMAN-driven)
  • PostgreSQL / TimescaleDB
  • MySQL / MariaDB
  • SAP HANA on-site
Infrastructure · Configs
Network & OS
  • Cisco IE / Stratix switch configs
  • Hirschmann / Moxa industrial switches
  • Fortinet / Palo Alto firewall configs
  • Engineering workstation (EWS) full images
  • Server bare-metal / VM-level images

Three destinations · customer chooses

Destination · 01
On-site Edge appliance

Backups land on the LANAWARE Edge Node itself (Industrial form factor only). Fastest recovery path — minutes, not hours — and the data never leaves the customer's building. Ideal for plants on isolated networks or under air-gap policy.

RPO 15m · RTO < 1h · Up to 4 TB on-node
Destination · 02
Customer's own datacentre

For organisations whose corporate policy requires backups stay inside their own infrastructure. ECHO replicates encrypted backup chains to an SMB / NFS / S3-compatible target the customer owns. CM operates the workflow; the customer holds the storage.

RPO 15m · RTO 2–4h · Customer-defined retention
Destination · 03
CM Ontario private datacentre

For everything else, backups land in CM's owned-and-operated Tier III facility in Ontario, Canada — SOC 2 audited, data-residency guaranteed. Replicated to a paired site for disaster scenarios. No hyperscaler in the path.

RPO 15m · RTO 1–2h · Geo-paired in-province
echo.lanaware.com — Backup completion log · Site Delta
● Healthy
04:00:14 PLC-104 · Siemens S7-1515-2 PN program · 2.1 MB · checksum verified Success 14m
04:02:48 HMI-Cell3-A · WinCC Unified project · 487 MB · diff from prev = 4.1 MB Success 3m
04:08:11 IGN-GW-01 · Ignition gateway backup (.gwbk) · 1.4 GB · 17,432 tags Success 9m
04:21:33 HIST-PI-02 · PI archive segment 2025-Q4 · re-tried after lock contention Retried 22m
04:44:02 SQL-MES-A · MES SQL Server (Always-On listener) · 38 GB diff backup Success 19m
04:58:00 Restore-test · Scheduled bare-metal restore of EWS-12 image to sandbox host · checksum ok Verified —
09

Backups that are proven, not assumed

Every backup chain is automatically test-restored on a schedule to an isolated sandbox host. An untested backup is a hope, not a recovery plan. ECHO produces a verified-restore evidence trail auditors can read.

10

Application-consistent, OT-aware

Backups respect batch boundaries, historian write windows, and SQL Always-On listener state. ECHO won't open a transaction mid-recipe or steal an Ignition gateway lock during a tag-write burst.

11

Recovery workflow — engineering shadow

One-click rollback for routine restores (HMI page edit gone wrong, accidental tag delete). For full DR, a CM engineer shadows the customer through the restore — even at 3am — so the person executing recovery isn't the one learning the runbook.

12

Compliance evidence by default

Backup completion records, restore-test records, retention attestations, and chain-of-custody exports — generated as a side-effect of normal operations, not as a quarterly scramble. Mapped to NERC-CIP CIP-009, IEC 62443-2-4, ISO 27001 A.12.3, and NIST CSF RC.RP.

15m
Default RPO
< 1h
RTO · on-site restore
3
Backup destinations
0
Public cloud in path
Section 08 / Managed virtualization (MVE)

Plant-floor HA without a datacentre.

Most plants need high-availability for SCADA, historians, batch managers, and MES connectors — but don't have rack space, cooling, a dedicated DC engineer, or any appetite for shipping production data to a hyperscaler. Managed Virtualization Environment (MVE) drops a redundant, CM-operated virtualization stack on-site (or hosted from CM's Ontario private DC) and integrates it into the LANAWARE monitoring & backup fabric automatically.

01

Hypervisor of your choice — or ours

Customer-led shops keep what they know: VMware vSphere, Microsoft Hyper-V, Oracle VM, KVM, or Proxmox. Greenfield sites usually take CM's KVM/Proxmox reference stack — same outcome, no license tax, easier OT-aware tuning.

02

Industrial-aware HA & failover

Failover policies tuned to OT realities. The cluster won't restart a SCADA service mid-batch, won't break an operator's HMI session at shift change, and won't fail back during a recipe transition. Generic VMware HA gets you uptime; MVE gets you uptime without surprising the plant.

03

Stretched on-prem cluster

Two MVE nodes deployed across separate electrical panels, or two adjacent rooms, or two ends of the plant. Single plant, real redundancy — no WAN dependency for failover. Recommended baseline for any production-critical stack.

04

Hosted option — Ontario private DC

For sites where on-prem virtualization isn't practical (space, cooling, change control), MVE runs in CM's Ontario private DC over the LA Conduit Tunnel. Customer's industrial apps look local; the steel is ours.

05

Edge Node sees inside the VMs

The LANAWARE Edge Node discovers the host cluster, the guests inside, the OS, and the industrial applications running on those guests — all the way down to a WinCC tag database or an Ignition gateway. MVE is just another monitored asset.

06

Backups by default — via ECHO

Every MVE guest is enrolled into ECHO automatically. VM-level snapshots plus application-consistent backups of the workload inside. No "we'll set up backups later." Day-one protection.

07

Patch & lifecycle managed by CM

Hypervisor updates, security patches, firmware, and BIOS — all maintained on a managed cadence by CM, scheduled against real plant windows, not generic Patch Tuesday. With evidence captured for audit.

08

When the SCADA workstation is the SCADA workstation

MVE explicitly supports virtualising operator workstations (OWS) and engineering workstations (EWS), with thin-client access from the plant floor. HMIs survive when the steel under them dies. Spare OWS is a VM clone, not a forklift.

MVE-HOST-A · 192.168.40.11 Active
scada-primary · Ignition 8.134% CPU · 12 GB
hist-pi-01 · PI Data Archive18% CPU · 24 GB
sql-mes-a · SQL Server 2022 AG22% CPU · 32 GB
ews-engineering-01 · Win11 EWSlive-migrating →
batch-mgr · Wonderware AppEng9% CPU · 8 GB
MVE-HOST-B · 192.168.40.12 Passive · ready
scada-secondary · Ignition redundant11% CPU · 12 GB
sql-mes-b · SQL Server 2022 AGreplica · synced
ows-line2-a · OWS clone (cold)spare image · 0%
ows-line2-b · OWS clone (cold)spare image · 0%
ews-engineering-02 · Win11 EWS↳ receiving migration
N+1
Standard redundancy
5
Hypervisors supported
< 30s
HA failover · steady state
0
Hyperscaler dependency
07 Hardware, architecture, install & grow Form factors · Data isolation · Zero-touch install · Subscription expansion · Screenshots
Section 09 / The hardware

Three form factors. One software stack.

Every LANAWARE Edge Node — regardless of form factor — runs the same software and reports back to the same control plane. The hardware is sized to the scan workload, not the feature set.

Standard · Available

LANAWARE Edge Node — Compact

A small-footprint LANAWARE Edge Node sized for lab, demo, and low-cost SMB deployments. Ideal for proof-of-concept rollouts and single-site pilots ahead of broader fleet adoption.

Form factor · Small-board · Fanless
Industrial · Available

LANAWARE Edge Node — Industrial

A hardened, fanless mini-PC LANAWARE Edge Node engineered for production deployments. WAN, LAN, and dedicated management interfaces. The default choice for typical industrial sites.

Form factor · Fanless mini-PC · 3-port
Roadmap · 2026

LANAWARE Edge Node — High-Density

A larger LANAWARE Edge Node appliance for high-throughput sites and dense subnet sweeps. Targets enterprises with very large IT and OT estates collapsed into a single facility.

Form factor · Rackable · High-throughput
Section 10 / Architecture

Engineered for customer-data isolation.

The architecture below is not a marketing diagram — it is the contract LANAWARE Edge enforces in software. Every choice reinforces the same principle: a customer's data is theirs, and only theirs.

  • Hardened edge runtime
    A LANAWARE Edge Node runs a containerised, hardened software stack on a minimised Linux foundation. The footprint is small enough for industrial hardware, robust enough for production.
  • Per-customer data isolation
    Each customer's scan data lives in its own physically separate embedded database file. Cross-customer reads are architecturally impossible — no shared tables, no foreign keys across customer boundaries.
  • Shared, curated knowledge base
    Reference data — vendor identifiers, vulnerability feeds, industrial-device fingerprints, OID maps, vendor logos — is centrally curated and replicated read-only to the edge. Customer data never enters that channel.
  • Dual-WebSocket control plane
    A permanent secure channel to the Registrar service identity · entitlements · diagnostics and an optional data-plane channel to the customer's LANAWARE Cloud environment for fleet sync (Cloud-mode only). Two separations, one cable.
  • REST API & webhook integrations
    A clean REST interface for integration with SIEM, SOAR, and ticketing systems; webhook notifications for new devices, new vulnerabilities, and device-down events.
  • Browser-based UI
    Nothing to install on the customer side. Any modern browser is enough — the LANAWARE Edge Node serves its own administrative interface locally and securely.
Fig.02 / Isolation contract EDGE NODE RUNTIME CONTAINERIZED CUSTOMER · A data.db CUSTOMER · B data.db CUSTOMER · C data.db KNOWLEDGE BASE READ · ONLY REGISTRAR ID · ENTITLEMENT LANAWARE CLOUD OPTIONAL · DATA PLANE CLOUD-MODE ONLY
Section 11 / See it in action

From the node. From the cloud.

You've seen the Assets table, the Purdue topology, the risk posture, the traffic health, and the network-map designer. They all live in the same place — a LANAWARE Edge Node's local browser UI, served on the customer's network for on-site operations. LANAWARE Cloud's Registrar gives MSPs and multi-site operators the same data through a fleet-wide pane.

edge-node.local:8000
LANAWARE Edge Node dashboard in dark theme
Fig. 06 · LANAWARE Edge Node — Dashboard Interfaces · Subnets · Scan Jobs
registrar.lanaware.com/nodes
Fig. 07 · LANAWARE Cloud — Fleet Registrar Fleet-wide · Multi-tenant
Section 12 / Zero-touch provisioning

Unbox. Plug in. Done.

No imaging, no CLI, no truck roll for ongoing operations. Once the LANAWARE Edge Node phones home, the customer's existing organisation, sites, tiers, and feature modules apply automatically.

Step 01

Unbox

The LANAWARE Edge Node ships pre-licensed and labelled for the customer. Nothing to image, nothing to configure on-site.

Step 02

Plug in

Power and a single uplink cable. The node negotiates its connection through whatever WAN is available — wired, cellular, or otherwise.

Step 03

Phone home

The node identifies itself to the Registrar using its hardware fingerprint and a one-time bootstrap token from the customer portal.

Step 04

Inherit policy

Customer organisation, sites, scan tiers, and subscribed feature modules apply automatically. The node is live within minutes.

Section 13 / Subscription expansion

Add capability without a site visit.

LANAWARE Edge ships with a base capability and grows through feature modules — added, removed, or reassigned from the cloud portal without rebooting the node, swapping hardware, or sending an engineer to site.

Base subscription · Today
Discovery & Monitoring

Network mapping, asset classification, SNMP health, topology, and the safety-tiered scan engine — included with every LANAWARE Edge Node.

Discovery Classification SNMP Health Topology
Expansion · Add anytime
Tier & module upgrades

Operator clicks a button at the cloud portal; the LANAWARE Edge Node pulls the new feature module and turns it on. No truck roll. No downtime.

Vulnerability Intelligence OT Deep-Protocol Compliance Evidence Surveillance & Security Monitoring Service Monitoring — more modules in flight
Section 15 / Who it's for

Who buys LANAWARE Edge

LANAWARE Edge is purpose-built for organisations that need real visibility into both their IT and OT estate — without the cost, complexity, or operational risk of traditional enterprise-only asset platforms.

Industrial operators

Manufacturing, water, energy, and building automation teams needing OT asset inventory and vulnerability tracking without disrupting production.

Critical infrastructure

Organisations required to comply with NERC-CIP, IEC 62443, or NIS2, and to produce audit-ready evidence on demand.

MSPs & MSSPs

Service providers deploying LANAWARE Edge at customer sites and managing the entire fleet centrally from one pane of glass.

SMB & mid-market IT

Teams that want enterprise-grade asset discovery and vulnerability intelligence without enterprise budgets or licensing models.

Section 16 / Honest scope

What LANAWARE Edge is not

We sell LANAWARE Edge for what it does well, not for what it isn't. Knowing where the product stops is part of how we keep customer trust.

×
Not a SIEM

It feeds inventory and findings into your SIEM via REST and webhooks. It doesn't itself ingest logs.

×
Not an EDR

It doesn't run on endpoints. It observes them on the network — which is precisely why OT endpoints stay safe.

×
Not an exploit-testing scanner

It identifies known vulnerabilities from software fingerprinting. It doesn't actively exploit-test the way a penetration-testing scanner would.

×
Not a packet broker

It can capture pcaps for forensic and OT-protocol analysis, but it doesn't replace dedicated capture infrastructure.

Start with a single LANAWARE Edge Node

Pilot it. Prove it. Scale when you're ready.

Talk to our team about a LANAWARE Edge pilot for your site or fleet. We'll size the right form factor for your environment, confirm Cloud or Local mode for your data-residency needs, and walk you through what the first thirty days look like.

PHONE
1 (647) 478-8810
SALES
sales@completelymanaged.com
SUPPORT
info@completelymanaged.com